The shape of the room defines the movement of the sound waves within the room. Placement of acoustic materials should be determined by the way the sound moves in that particular room in order to ensure optimal efficiency of the materials.

1. NARROW ROOMS 

Placing the sound absorbing materials on the ceiling in a narrow room will not create the wanted acoustic effect. 

Sound absorbers must be placed as close to the sound source as possible. Therefore, the absorbing materials must primarily be placed on the walls

2.ROUND ROOMS 

The sound moves towards the constructive centre thereby creating echoes.

The sound diffusing elements should be placed on the curved surfaces in order for the sound to be dispersed in many directions.

3.1 LARGE ROOMS WITH LOW CEILING

In large rooms the sound spreading is experienced as the greatest challenge, since the speech sounds can be heard over long distances.

Sound absorbing and sound diffusing materials should be used, and sound barriers should be applied to the ceiling. The sound regulation from the floor is secured by furniture and the use of sound barriers.

3.2. LARGE ROOMS WITH HIGH CEILING

The acoustic environment in large rooms is sometimes experienced as the one at a railway station. This is partially connected to the fact that it is difficult to concentrate due to the relatively high noise level. Another reason for this is the fact that the conversation over short distances is impeded due to the sound being masked or drowned by the surrounding noise 

It is therefore important that all the available surfaces are equipped with effective sound absorbers and sound diffusers. The furniture along with the sound barriers play a highly active role by diffusing the sound and thereby making the existing sound absorbers and diffusers even more efficient.

4. SMALL ROOM WITH PARALLEL WALLS 

In small rooms, the low frequencies often seem to be predominant. Therefore, the speech appears to consist primarily of humming sounds. Sound absorbers with a low-frequency profile should be used and placed on the ceiling surface.

5. CEILING DOMES

The sound diffusing elements should be placed on the curved surfaces in order for the sound to be dispersed in many directions.

6. INCLINED CEILING

Inclined ceilings have both a sound spreading and a sound concentrating effect. In most cases, the sound is concentrated because the sound regulation of the area around the inclined ceiling has not been considered carefully.

The wall area opposite the inclined ceiling should also be equipped with sound absorbing materials. As a principal rule, all surfaces above the normal ceiling height (2.60 m) including the end walls should be equipped with sound absorbers.

7.INCLINED WALLS

Inclined walls have both a sound spreading and sound concentrating effect. 

The sound spreading effect is achieved by inclining the wall in proportion to other walls and the ceiling. In general, the walls inclined by more than 6 degrees ensure an excellent sound diffusion. The most effective diffusion is obtained by applying several angles.

8. VAULTED CEILING

In rooms with vaulted ceilings, the sound is concentrated in the constructive centre making the sound appear with a stronger intensity. The sound movements also appear stronger along the curve.

9. CONNECTED ROOMS

Rooms that are linked by a large opening in between, influence each others sound environment. A room without acoustic regulation can act as an echo chamber reinforcing the sound, when connected to an acoustically regulated room.

Both rooms must be equipped with sound absorbers. If the distance between the opening and the opposite walls is short (5-6 m), the walls much be covered with sound absorbers or diffusers.

10. ROOMS WITH MEZZANINE

In rooms with mezzanine, it is possible to create different sound environments in the same room. In the large, open room, an environment with long reverberation time is created. The space above and below the mezzanine has a shorter reverberation time. The challenge posed in this type of rooms is the sound reflection and the harmonization of the different reverberation times.

The wall opposite the mezzanine should be equipped with sound absorbers or diffusers. In addition, sound absorbers should be placed on the underside and the banister of the mezzanine. In order to prevent large differences in the reverberation times between the large room and the space around the mezzanine, sound barriers can be applied.

Credit: KNAUF DANOLINE

Check out our free reverberation online calculator (for basic rooms).

https://www.geonoise.com/reverberation-time-calculator/

Kategori
Asia Noise News Environment

Noise in Malaysia

What Covid-19 did to Malaysia

2020 has been a year full of ups and downs. One big thing that affected, in fact, is still affecting the whole world is undeniably the Covid-19 pandemic. No doubt that the pandemic has caused a lot of downhills in the development of many aspects, like economy and social, but there is one thing that have shown obvious positive sign during this situation: the environmental change.

Figure 1 A picture showing the clearer skies in Kuala Lumpur, the capital of Malaysia (Photos: Filepic).

According to a Malaysian news report by Ming Teoh from The Star, the movement control order (MCO) that was carried out to tackle the Covid-19 spread in Malaysia has brought positive environmental impacts to the country (Teoh, 2020). People were amazed by the clean rivers, clear blue skies and the recovery of nature and wildlife. Of course, due to the MCO where a lot of human activities were restricted, the streets and urban roads have been very quiet as compared to the usual noise level. The improved noise quality resulted in lower noise pollution, which made the sounds of the fauna more apparent. But once everyone gets back to normal life when the MCO is lifted, how long can this positive environmental situation last? Will there be enough time for the environment to heal properly?

The Department of Environment (DOE), Ministry of Energy, Science, Technology, Environment and Climate Change (MESTECC), Malaysia

The Department of Environment (DOE) from the Ministry of Energy, Science, Technology, Environment and Climate Change (MESTECC) of Malaysia have been very concerned about this issue all the while, specifically on the noise quality of the country. They have constantly been updating the guidelines to handle noise or vibration for various applications, for example vehicle-noise, ambient noise, or outdoor noise sources in the environment. In one of the published guidelines for environmental noise limits and control (2009), the DOE have specified a table showing the permissible sound levels for different applications, shown in Table 1 as one of the examples from the guidelines (Air & Noise, 2019). 

Table 1 An example of the permissible sound levels listed in the guidelines published by the DOE.

The permissible sound levels differ by the applications (i.e. use of land, human density) and the different times of the day, to ensure that the circumstances of various conditions are taken into account during the sound level measurements. For instance, the ambient noise limits are set such that it is an absolute limit based on the average level of noise (which should not be exceeded in a specified period), or in accordance with a relative limit based on the permitted increase in noise level with respect to the background level. It is mentioned that the limits should always be consistent with the environmental noise climate of the location. The rest of the noise limit schedules listed in the guidelines include those for land use, road traffic, railway/transit trains, construction, and maintenance, which are the main sources of outdoor noise in the country. 

Besides that, the report also covers guidelines on planning process, noise impact assessments, quantifying of noise disturbance, and guidance in environmental noise mitigation through planning and control. These are ideally applied in new and existing projects planning, in which the projects can cover anything that involves noise, as a potential concern or needed to be measured and assessed. This is a very imperative measure from the DOE to enforce noise control in the country to work on controlling the noise impact of the relevant applications, thus overcoming the noise pollution in Malaysia. With these actions being taken and followed, the goal to maintaining a better noise quality in the country can be achieved in near future.

Written by:

Khei Yinn Seow

Mechanical Engineer

Geonoise Malaysia

khei@geonoise.asia 

References:

Air & Noise, P. S. C. S., 2019. Guidelines for Environmental Noise Limits and Control (Third Edition), Putrajaya: Department of Environment Malaysia.

Teoh, M., 2020. Blue skies, less waste: Covid-19 and the MCO’s effects on the environment., s.l.: The Star.

Kategori
Asia Noise News Building Acoustics Environment Industrial Vibration

Building Vibration Limits in Indonesia

A lot of activities and businesses have the potential to have negative effects to their environment because of the vibration that they produce. For example, construction (for example during piling), mining and and other vibration-generating activities. This vibration can disturb the comfort and health of people around it, and even can have destructive effects to nearby buildings.

In Indonesia, the vibration limit is regulated through Ministerial Decree of Ministry of Environment No. 49 Year 1996. This regulation was made to ensure healthy environment for human and other living creatures to live in. Consequently, the vibration generated from human activities need to be regulated.

In this regulation, businesses and activities are required to:

  1. Comply to the vibration limit in the decree. This is required for businesses and activities to obtain certain relevant permits to be able to operate.
  2. Use vibration reduction equipment
  3. Report vibration monitoring activities at least once in 3 (three) months to the Governor, Minister, Government agencies that are responsible to control environmental impact, other technical institutions that is responsible for the activities and other organizations that might need the vibration monitoring report.

The vibration limit is separated into few parts which are:

  1. Vibration limits for health and comfort
  2. Mechanical vibration limits based on its destructive effects
  3. Mechanical vibration limits based on building types
  4. Shock limits

The following table and graphs is the vibration limit for health and comfort:

Conversion:

Acceleration = (2πf)2 x displacement

Velocity = 2πf x displacement

The graphic representation of the table above is as follows:

The table below is the vibration limits based on the destructive effects:

As seen above, the peak velocity limit from the vibration is separated into 4 categories which are:

  • Category A: non-destructive
  • Category B: Possibly destructive for plastering (crack, or in certain cases the plaster can fell off the wall) 
  • Category C: Possibly destructive for structural components that bear loads
  • Category D: High risk of destruction of load bearing walls

The following graph is the vibration limit based on destructive effects in a graphical form:

Mechanical vibration limit can also be categorized into the types of buildings. The buildings are categorized into 3 which are:

  1. Buildings for commercial, industrial, and other similar use.
  2. Residential and other buildings with similar design and usage
  3. Structures that are sensitive to vibration and cannot be categorized into category 1 and 2, for example preserved buildings with high cultural value

Below is the vibration limits for the building category above:

The table below is shock limit for buildings:

CategoryBuilding TypeMaximum velocity (mm/s)
1Old buildings with high historical value2
2Buildings with existing defects, cracks can be seen on the walls5
3Buildings with good condition, minor cracks on plaster is acceptable10
4Buildings with high structural strength (for example industrial building which is made from concrete and steel)10 – 40

The ministerial decree also describe the measurement and analysis method for vibration as follows:

  1. Instruments:
    1. Vibration transducer (Accelerometer or seismometer)
    2. Vibration measurement device or analysis device (Vibration meter or vibration analyzer)
    3. 1/3 octave or narrow band filter
    4. Signal recorder
    5. FFT Analyzer
  2. Measurement procedure:
    1. Vibration measurement related with health and comfort:
      • Place transducer on the floor or other vibrating surface, and connect it to the measuring device with filtration
      • Set the measuring instruments to measure displacement. If the measuring instruments do not have that on display, the conversion from acceleration or velocity can be used
      • Reading and recording is conducted for frequency between 4-63 Hz or with signal recording device
      • Measurement results with at least 13 data shall be plotted on graph
    2. Vibration measurement for structural health:
      • The measurement method is similar with the vibration measurement above, however the physical measure that is assessed is the peak velocity.
    3. Evaluation
      • The 13 data which are plotted on graph shall be compared with the vibration limits. The vibration is considered above the limit if the vibration level exceeds the limit at any frequency.

Definition

The definition used in the regulation of ministry of environment No 49 Year 1996 is as follows:

  1. Building structure is a part of building that is planned, calculated, and functioned to:
    • Support any kind of load (static load, dynamic load, and temporary load)
    • Functioned for building’s stability as a whole. For example: frame and bearing wall
  2. Structure’s component is a part of a building structure that contributes to structure’s function. For example: beams, columns, and slab.
  3. Bearing wall is a building structure which is a vertical plane that is functioned to support loads on top of it such as slab or roof.
  4. Non-structure components are parts of building that is not planned or functioned to support load. For example partition walls, door and window frames, etc.

Destructive impact on structure and non-structure:

  1. Destructive impact on structure: Destructive impacts that can endanger building stability (for example destruction of columns that potentially make a building collapses)
  2. Destructive impact on non-structure: Not dangerous to building stability, but can be a danger for building occupants (for example: when a partition wall collapses, it will not make the building collapse, but can injure occupants)

Degree of building destruction:

  1. Light: not dangerous for building stability and can be fixed without reducing building’s strength
  2. Moderate: Destruction that can reduce structural strength. To fix this, added reinforcement must be used.
  3. Severe: Degree of destruction that can endanger the building and potentially makes the building collapses.

Written by:

Hizkia Natanael
Acoustic Engineer
Phone: +6221 5010 5025
Email: hizkia@geonoise.asia

Kategori
Asia Noise News Building Accoustics Environment Industrial

Noise Level Prediction in Industry (Oil & Gas, Power Generation, Process, etc.)

Most industrial activities create noise that can be harmful to the environment as well as to their workers. To minimize this effect, governments, associations, and companies have created regulations, standards, and codes to set the allowable noise both inside the sites, that can be harmful to the workers, as well as to the environment. In a lot of cases, during the planning phase, the plant owner and project management want to be sure that the noise levels are acceptable. Since the plant is not built yet, what can be done is creating a noise model to simulate the plant, so that the noise levels can be predicted. In this article, we will explore how we can do so.

The first thing we must know is how much noise does the noise sources inside of the plant will emit. The noise source is usually described in two ways which is Sound Power Level (Lw or SWL), and Sound Pressure Level (Lp or SPL) in certain distance, most commonly Lp in 1 m distance. There are multiple ways to get this information for certain noise sources. First, if the equipment type and model have been chosen, the equipment manufacturer will normally report the noise level in their datasheet. However, this is not usually the case with most of noise predictions since the noise study is normally done before the equipment suppliers are appointed. So, the second way to be able to predict the noise emission is by following empirical formulas that are developed by researchers. You can find such formulas in some textbooks, journals, and papers. For rotating parts, you will need its rated power and rotational speed to be able to estimate the noise emission. 

For example, in the speed range of 3000-3600 rpm, the noise level of a pump with drive motor power above 75 kW can be predicted using the following equation:

Suppose a pump with rotational speed of 3000 rpm and 100 kW, according to the formula, it can be estimated that the noise level at 1 m from the pump would be 92 dB. And suppose the noise source can be considered as point source on the ground (hemisphere propagation), the sound power level of the pump can be calculated using the following formula:

Where r is the distance from source to receiver

And in this case, the predicted Lw would be 100 dB.

Thirds, noise measurement to a similar equipment can also be an option to be able to determine the noise level of the new equipment. Another option, in some countries, there are noise emission limit for certain equipment, you can use that limit if it is applicable for your project.

After the Lw of all noise sources is obtained, we want to calculate the noise levels (the Lp) at the receivers. There are some standards which procedure can be followed to calculate this. Few of which are ISO 9613-2, NORD 2000, CNOSSOS EU, and many others. Most of the standards consider some factors to the calculation such as distance, atmospheric absorption, ground reflection, screening effect (from barriers and obstacles) and other factors such as volume absorption from vegetation, industrial site, etc. Most consultants and projects will require a software such as SoundPLAN to do this calculation.

Depending the project, there are few types of noise limit which compliance will need to be ensured. The most common ones are environmental noise limit, noise exposure limit, area noise limit and absolute noise limit. Besides, the noise level during emergency is also modelled so that the information can be used for safety and PAGA (Public Address and General Alarm) study.

Environmental noise limit is usually calculated for the plant’s contribution to the plant’s boundary as well as to the nearest sensitive receiver such as residential and school near the plant. How this is accessed depends on the regulation applicable on the plant area. In Indonesia for example, the noise limit for residential area is Lsm 55 dBA and industrial area is Lsm 70 dBA. Lsm is a measure like Ldn, but the night noise level addition is 5 dB instead of the 10 dB addition that most other countries, especially Europeans use. To ensure compliance with this regulation, the noise level at fence should be less than Lsm 70 dBA, and suppose there is a residential area nearby, the contribution from the site should be less than 55 dBA. It is also advisable to measure the existing noise level at the sensitive receivers to make the study more relevant to the situation. 

Noise exposure limit is the maximum exposure to noise that the workers get during their working period. In Indonesia, the noise exposure limit is 85 dBA for 8 working hours. To change the working hours, 3 dB exchange rate is used. For example, if the noise level in the plant is 88 dBA, then the workers can only work there for 4 hours, if it is 91 dBA, then the time limit is 2 hours, and so on. To extend the working hours on a noisy area, the options are to actually reduce the noise level by reducing the noise emission from the source or noise control at transmission (for example using barrier), or by usage of Hearing Protection Device (HPD) for the workers such as ear plugs and ear muffs. The noise exposure of workers after usage of HPD can be calculated using the following formula:

Where NRR is the noise reduction rating of the HPD in dB.

Different area might have different noise level limits, and therefore area noise limits are useful. For example, in an unmanned mechanical room, the noise level can be high, for instance 110 dBA. However, inside of the site office, the allowable noise level is much lower, for example 50 dBA. This noise level shall be calculated to ensure compliance with the noise limit. Different companies might have different limits for this to ensure their employees’ health and productivity. If the area is indoor and the noise source is outdoor, then the interior noise level can be estimated using standards such as ISO 12354-3. 

The absolute noise limit is the highest noise level allowable at the plant, and shall not be exceeded at any times, including emergency. In most cases, the absolute noise limit for impulsive sound is 140 dBA. To ensure compliance with this requirement, potential high-level noise shall be calculated, for example safety valves.

During emergency, different noise sources than normal situation will be activated, such as flare, blowdown valves, fire pumps, and other equipment. In such cases, the sound from the alarm and Public Address system must be able to be heard by the workers inside of the plant. Normally the target for the SPL from the PAGA system should be higher than 10 dB above the noise level. Therefore, the noise level during emergency in each area should be well-known. 

Written by:

Hizkia Natanael
Acoustic Engineer
Phone: +6221 5010 5025
Email: hizkia@geonoise.asia

Kategori
Asia Noise News Building Accoustics Environment Industrial

Noise Level Prediction in Industry (Oil & Gas, Power Generation, Process, etc.)

Most industrial activities create noise that can be harmful to the environment as well as to their workers. To minimize this effect, governments, associations, and companies have created regulations, standards, and codes to set the allowable noise both inside the sites, that can be harmful to the workers, as well as to the environment. In a lot of cases, during the planning phase, the plant owner and project management want to be sure that the noise levels are acceptable. Since the plant is not built yet, what can be done is creating a noise model to simulate the plant, so that the noise levels can be predicted. In this article, we will explore how we can do so.

The first thing we must know is how much noise does the noise sources inside of the plant will emit. The noise source is usually described in two ways which is Sound Power Level (Lw or SWL), and Sound Pressure Level (Lp or SPL) in certain distance, most commonly Lp in 1 m distance. There are multiple ways to get this information for certain noise sources. First, if the equipment type and model have been chosen, the equipment manufacturer will normally report the noise level in their datasheet. However, this is not usually the case with most of noise predictions since the noise study is normally done before the equipment suppliers are appointed. So, the second way to be able to predict the noise emission is by following empirical formulas that are developed by researchers. You can find such formulas in some textbooks, journals, and papers. For rotating parts, you will need its rated power and rotational speed to be able to estimate the noise emission. 

For example, in the speed range of 3000-3600 rpm, the noise level of a pump with drive motor power above 75 kW can be predicted using the following equation:

Suppose a pump with rotational speed of 3000 rpm and 100 kW, according to the formula, it can be estimated that the noise level at 1 m from the pump would be 92 dB. And suppose the noise source can be considered as point source on the ground (hemisphere propagation), the sound power level of the pump can be calculated using the following formula:

Where r is the distance from source to receiver

And in this case, the predicted Lw would be 100 dB.

Thirds, noise measurement to a similar equipment can also be an option to be able to determine the noise level of the new equipment. Another option, in some countries, there are noise emission limit for certain equipment, you can use that limit if it is applicable for your project.

After the Lw of all noise sources is obtained, we want to calculate the noise levels (the Lp) at the receivers. There are some standards which procedure can be followed to calculate this. Few of which are ISO 9613-2, NORD 2000, CNOSSOS EU, and many others. Most of the standards consider some factors to the calculation such as distance, atmospheric absorption, ground reflection, screening effect (from barriers and obstacles) and other factors such as volume absorption from vegetation, industrial site, etc. Most consultants and projects will require a software such as SoundPLAN to do this calculation.

Depending the project, there are few types of noise limit which compliance will need to be ensured. The most common ones are environmental noise limit, noise exposure limit, area noise limit and absolute noise limit. Besides, the noise level during emergency is also modelled so that the information can be used for safety and PAGA (Public Address and General Alarm) study.

Environmental noise limit is usually calculated for the plant’s contribution to the plant’s boundary as well as to the nearest sensitive receiver such as residential and school near the plant. How this is accessed depends on the regulation applicable on the plant area. In Indonesia for example, the noise limit for residential area is Lsm 55 dBA and industrial area is Lsm 70 dBA. Lsm is a measure like Ldn, but the night noise level addition is 5 dB instead of the 10 dB addition that most other countries, especially Europeans use. To ensure compliance with this regulation, the noise level at fence should be less than Lsm 70 dBA, and suppose there is a residential area nearby, the contribution from the site should be less than 55 dBA. It is also advisable to measure the existing noise level at the sensitive receivers to make the study more relevant to the situation. 

Noise exposure limit is the maximum exposure to noise that the workers get during their working period. In Indonesia, the noise exposure limit is 85 dBA for 8 working hours. To change the working hours, 3 dB exchange rate is used. For example, if the noise level in the plant is 88 dBA, then the workers can only work there for 4 hours, if it is 91 dBA, then the time limit is 2 hours, and so on. To extend the working hours on a noisy area, the options are to actually reduce the noise level by reducing the noise emission from the source or noise control at transmission (for example using barrier), or by usage of Hearing Protection Device (HPD) for the workers such as ear plugs and ear muffs. The noise exposure of workers after usage of HPD can be calculated using the following formula:

Where NRR is the noise reduction rating of the HPD in dB.

Different area might have different noise level limits, and therefore area noise limits are useful. For example, in an unmanned mechanical room, the noise level can be high, for instance 110 dBA. However, inside of the site office, the allowable noise level is much lower, for example 50 dBA. This noise level shall be calculated to ensure compliance with the noise limit. Different companies might have different limits for this to ensure their employees’ health and productivity. If the area is indoor and the noise source is outdoor, then the interior noise level can be estimated using standards such as ISO 12354-3. 

The absolute noise limit is the highest noise level allowable at the plant, and shall not be exceeded at any times, including emergency. In most cases, the absolute noise limit for impulsive sound is 140 dBA. To ensure compliance with this requirement, potential high-level noise shall be calculated, for example safety valves.

During emergency, different noise sources than normal situation will be activated, such as flare, blowdown valves, fire pumps, and other equipment. In such cases, the sound from the alarm and Public Address system must be able to be heard by the workers inside of the plant. Normally the target for the SPL from the PAGA system should be higher than 10 dB above the noise level. Therefore, the noise level during emergency in each area should be well-known. 

Kategori
Asia Noise News Building Accoustics Environment Industrial

Noise Level Prediction in Industry (Oil & Gas, Power Generation, Process, etc.)

Most industrial activities create noise that can be harmful to the environment as well as to their workers. To minimize this effect, governments, associations, and companies have created regulations, standards, and codes to set the allowable noise both inside the sites, that can be harmful to the workers, as well as to the environment. In a lot of cases, during the planning phase, the plant owner and project management want to be sure that the noise levels are acceptable. Since the plant is not built yet, what can be done is creating a noise model to simulate the plant, so that the noise levels can be predicted. In this article, we will explore how we can do so.

The first thing we must know is how much noise does the noise sources inside of the plant will emit. The noise source is usually described in two ways which is Sound Power Level (Lw or SWL), and Sound Pressure Level (Lp or SPL) in certain distance, most commonly Lp in 1 m distance. There are multiple ways to get this information for certain noise sources. First, if the equipment type and model have been chosen, the equipment manufacturer will normally report the noise level in their datasheet. However, this is not usually the case with most of noise predictions since the noise study is normally done before the equipment suppliers are appointed. So, the second way to be able to predict the noise emission is by following empirical formulas that are developed by researchers. You can find such formulas in some textbooks, journals, and papers. For rotating parts, you will need its rated power and rotational speed to be able to estimate the noise emission. 

For example, in the speed range of 3000-3600 rpm, the noise level of a pump with drive motor power above 75 kW can be predicted using the following equation:

Suppose a pump with rotational speed of 3000 rpm and 100 kW, according to the formula, it can be estimated that the noise level at 1 m from the pump would be 92 dB. And suppose the noise source can be considered as point source on the ground (hemisphere propagation), the sound power level of the pump can be calculated using the following formula:

Where r is the distance from source to receiver

And in this case, the predicted Lw would be 100 dB.

Thirds, noise measurement to a similar equipment can also be an option to be able to determine the noise level of the new equipment. Another option, in some countries, there are noise emission limit for certain equipment, you can use that limit if it is applicable for your project.

After the Lw of all noise sources is obtained, we want to calculate the noise levels (the Lp) at the receivers. There are some standards which procedure can be followed to calculate this. Few of which are ISO 9613-2, NORD 2000, CNOSSOS EU, and many others. Most of the standards consider some factors to the calculation such as distance, atmospheric absorption, ground reflection, screening effect (from barriers and obstacles) and other factors such as volume absorption from vegetation, industrial site, etc. Most consultants and projects will require a software such as SoundPLAN to do this calculation.

Depending the project, there are few types of noise limit which compliance will need to be ensured. The most common ones are environmental noise limit, noise exposure limit, area noise limit and absolute noise limit. Besides, the noise level during emergency is also modelled so that the information can be used for safety and PAGA (Public Address and General Alarm) study.

Environmental noise limit is usually calculated for the plant’s contribution to the plant’s boundary as well as to the nearest sensitive receiver such as residential and school near the plant. How this is accessed depends on the regulation applicable on the plant area. In Indonesia for example, the noise limit for residential area is Lsm 55 dBA and industrial area is Lsm 70 dBA. Lsm is a measure like Ldn, but the night noise level addition is 5 dB instead of the 10 dB addition that most other countries, especially Europeans use. To ensure compliance with this regulation, the noise level at fence should be less than Lsm 70 dBA, and suppose there is a residential area nearby, the contribution from the site should be less than 55 dBA. It is also advisable to measure the existing noise level at the sensitive receivers to make the study more relevant to the situation. 

Noise exposure limit is the maximum exposure to noise that the workers get during their working period. In Indonesia, the noise exposure limit is 85 dBA for 8 working hours. To change the working hours, 3 dB exchange rate is used. For example, if the noise level in the plant is 88 dBA, then the workers can only work there for 4 hours, if it is 91 dBA, then the time limit is 2 hours, and so on. To extend the working hours on a noisy area, the options are to actually reduce the noise level by reducing the noise emission from the source or noise control at transmission (for example using barrier), or by usage of Hearing Protection Device (HPD) for the workers such as ear plugs and ear muffs. The noise exposure of workers after usage of HPD can be calculated using the following formula:

Where NRR is the noise reduction rating of the HPD in dB.

Different area might have different noise level limits, and therefore area noise limits are useful. For example, in an unmanned mechanical room, the noise level can be high, for instance 110 dBA. However, inside of the site office, the allowable noise level is much lower, for example 50 dBA. This noise level shall be calculated to ensure compliance with the noise limit. Different companies might have different limits for this to ensure their employees’ health and productivity. If the area is indoor and the noise source is outdoor, then the interior noise level can be estimated using standards such as ISO 12354-3. 

The absolute noise limit is the highest noise level allowable at the plant, and shall not be exceeded at any times, including emergency. In most cases, the absolute noise limit for impulsive sound is 140 dBA. To ensure compliance with this requirement, potential high-level noise shall be calculated, for example safety valves.

During emergency, different noise sources than normal situation will be activated, such as flare, blowdown valves, fire pumps, and other equipment. In such cases, the sound from the alarm and Public Address system must be able to be heard by the workers inside of the plant. Normally the target for the SPL from the PAGA system should be higher than 10 dB above the noise level. Therefore, the noise level during emergency in each area should be well-known. 

Kategori
Asia Noise News Building Accoustics Environment Industrial

Noise Level Prediction in Industry (Oil & Gas, Power Generation, Process, etc.)

Most industrial activities create noise that can be harmful to the environment as well as to their workers. To minimize this effect, governments, associations, and companies have created regulations, standards, and codes to set the allowable noise both inside the sites, that can be harmful to the workers, as well as to the environment. In a lot of cases, during the planning phase, the plant owner and project management want to be sure that the noise levels are acceptable. Since the plant is not built yet, what can be done is creating a noise model to simulate the plant, so that the noise levels can be predicted. In this article, we will explore how we can do so.

The first thing we must know is how much noise does the noise sources inside of the plant will emit. The noise source is usually described in two ways which is Sound Power Level (Lw or SWL), and Sound Pressure Level (Lp or SPL) in certain distance, most commonly Lp in 1 m distance. There are multiple ways to get this information for certain noise sources. First, if the equipment type and model have been chosen, the equipment manufacturer will normally report the noise level in their datasheet. However, this is not usually the case with most of noise predictions since the noise study is normally done before the equipment suppliers are appointed. So, the second way to be able to predict the noise emission is by following empirical formulas that are developed by researchers. You can find such formulas in some textbooks, journals, and papers. For rotating parts, you will need its rated power and rotational speed to be able to estimate the noise emission. 

For example, in the speed range of 3000-3600 rpm, the noise level of a pump with drive motor power above 75 kW can be predicted using the following equation:

Suppose a pump with rotational speed of 3000 rpm and 100 kW, according to the formula, it can be estimated that the noise level at 1 m from the pump would be 92 dB. And suppose the noise source can be considered as point source on the ground (hemisphere propagation), the sound power level of the pump can be calculated using the following formula:

Where r is the distance from source to receiver

And in this case, the predicted Lw would be 100 dB.

Thirds, noise measurement to a similar equipment can also be an option to be able to determine the noise level of the new equipment. Another option, in some countries, there are noise emission limit for certain equipment, you can use that limit if it is applicable for your project.

After the Lw of all noise sources is obtained, we want to calculate the noise levels (the Lp) at the receivers. There are some standards which procedure can be followed to calculate this. Few of which are ISO 9613-2, NORD 2000, CNOSSOS EU, and many others. Most of the standards consider some factors to the calculation such as distance, atmospheric absorption, ground reflection, screening effect (from barriers and obstacles) and other factors such as volume absorption from vegetation, industrial site, etc. Most consultants and projects will require a software such as SoundPLAN to do this calculation.

Depending the project, there are few types of noise limit which compliance will need to be ensured. The most common ones are environmental noise limit, noise exposure limit, area noise limit and absolute noise limit. Besides, the noise level during emergency is also modelled so that the information can be used for safety and PAGA (Public Address and General Alarm) study.

Environmental noise limit is usually calculated for the plant’s contribution to the plant’s boundary as well as to the nearest sensitive receiver such as residential and school near the plant. How this is accessed depends on the regulation applicable on the plant area. In Indonesia for example, the noise limit for residential area is Lsm 55 dBA and industrial area is Lsm 70 dBA. Lsm is a measure like Ldn, but the night noise level addition is 5 dB instead of the 10 dB addition that most other countries, especially Europeans use. To ensure compliance with this regulation, the noise level at fence should be less than Lsm 70 dBA, and suppose there is a residential area nearby, the contribution from the site should be less than 55 dBA. It is also advisable to measure the existing noise level at the sensitive receivers to make the study more relevant to the situation. 

Noise exposure limit is the maximum exposure to noise that the workers get during their working period. In Indonesia, the noise exposure limit is 85 dBA for 8 working hours. To change the working hours, 3 dB exchange rate is used. For example, if the noise level in the plant is 88 dBA, then the workers can only work there for 4 hours, if it is 91 dBA, then the time limit is 2 hours, and so on. To extend the working hours on a noisy area, the options are to actually reduce the noise level by reducing the noise emission from the source or noise control at transmission (for example using barrier), or by usage of Hearing Protection Device (HPD) for the workers such as ear plugs and ear muffs. The noise exposure of workers after usage of HPD can be calculated using the following formula:

Where NRR is the noise reduction rating of the HPD in dB.

Different area might have different noise level limits, and therefore area noise limits are useful. For example, in an unmanned mechanical room, the noise level can be high, for instance 110 dBA. However, inside of the site office, the allowable noise level is much lower, for example 50 dBA. This noise level shall be calculated to ensure compliance with the noise limit. Different companies might have different limits for this to ensure their employees’ health and productivity. If the area is indoor and the noise source is outdoor, then the interior noise level can be estimated using standards such as ISO 12354-3. 

The absolute noise limit is the highest noise level allowable at the plant, and shall not be exceeded at any times, including emergency. In most cases, the absolute noise limit for impulsive sound is 140 dBA. To ensure compliance with this requirement, potential high-level noise shall be calculated, for example safety valves.

During emergency, different noise sources than normal situation will be activated, such as flare, blowdown valves, fire pumps, and other equipment. In such cases, the sound from the alarm and Public Address system must be able to be heard by the workers inside of the plant. Normally the target for the SPL from the PAGA system should be higher than 10 dB above the noise level. Therefore, the noise level during emergency in each area should be well-known. 

Kategori
Asia Noise News Building Accoustics Environment Industrial

Noise Level Prediction in Industry (Oil & Gas, Power Generation, Process, etc.)

Most industrial activities create noise that can be harmful to the environment as well as to their workers. To minimize this effect, governments, associations, and companies have created regulations, standards, and codes to set the allowable noise both inside the sites, that can be harmful to the workers, as well as to the environment. In a lot of cases, during the planning phase, the plant owner and project management want to be sure that the noise levels are acceptable. Since the plant is not built yet, what can be done is creating a noise model to simulate the plant, so that the noise levels can be predicted. In this article, we will explore how we can do so.

The first thing we must know is how much noise does the noise sources inside of the plant will emit. The noise source is usually described in two ways which is Sound Power Level (Lw or SWL), and Sound Pressure Level (Lp or SPL) in certain distance, most commonly Lp in 1 m distance. There are multiple ways to get this information for certain noise sources. First, if the equipment type and model have been chosen, the equipment manufacturer will normally report the noise level in their datasheet. However, this is not usually the case with most of noise predictions since the noise study is normally done before the equipment suppliers are appointed. So, the second way to be able to predict the noise emission is by following empirical formulas that are developed by researchers. You can find such formulas in some textbooks, journals, and papers. For rotating parts, you will need its rated power and rotational speed to be able to estimate the noise emission. 

For example, in the speed range of 3000-3600 rpm, the noise level of a pump with drive motor power above 75 kW can be predicted using the following equation:

Suppose a pump with rotational speed of 3000 rpm and 100 kW, according to the formula, it can be estimated that the noise level at 1 m from the pump would be 92 dB. And suppose the noise source can be considered as point source on the ground (hemisphere propagation), the sound power level of the pump can be calculated using the following formula:

Where r is the distance from source to receiver

And in this case, the predicted Lw would be 100 dB.

Thirds, noise measurement to a similar equipment can also be an option to be able to determine the noise level of the new equipment. Another option, in some countries, there are noise emission limit for certain equipment, you can use that limit if it is applicable for your project.

After the Lw of all noise sources is obtained, we want to calculate the noise levels (the Lp) at the receivers. There are some standards which procedure can be followed to calculate this. Few of which are ISO 9613-2, NORD 2000, CNOSSOS EU, and many others. Most of the standards consider some factors to the calculation such as distance, atmospheric absorption, ground reflection, screening effect (from barriers and obstacles) and other factors such as volume absorption from vegetation, industrial site, etc. Most consultants and projects will require a software such as SoundPLAN to do this calculation.

Depending the project, there are few types of noise limit which compliance will need to be ensured. The most common ones are environmental noise limit, noise exposure limit, area noise limit and absolute noise limit. Besides, the noise level during emergency is also modelled so that the information can be used for safety and PAGA (Public Address and General Alarm) study.

Environmental noise limit is usually calculated for the plant’s contribution to the plant’s boundary as well as to the nearest sensitive receiver such as residential and school near the plant. How this is accessed depends on the regulation applicable on the plant area. In Indonesia for example, the noise limit for residential area is Lsm 55 dBA and industrial area is Lsm 70 dBA. Lsm is a measure like Ldn, but the night noise level addition is 5 dB instead of the 10 dB addition that most other countries, especially Europeans use. To ensure compliance with this regulation, the noise level at fence should be less than Lsm 70 dBA, and suppose there is a residential area nearby, the contribution from the site should be less than 55 dBA. It is also advisable to measure the existing noise level at the sensitive receivers to make the study more relevant to the situation. 

Noise exposure limit is the maximum exposure to noise that the workers get during their working period. In Indonesia, the noise exposure limit is 85 dBA for 8 working hours. To change the working hours, 3 dB exchange rate is used. For example, if the noise level in the plant is 88 dBA, then the workers can only work there for 4 hours, if it is 91 dBA, then the time limit is 2 hours, and so on. To extend the working hours on a noisy area, the options are to actually reduce the noise level by reducing the noise emission from the source or noise control at transmission (for example using barrier), or by usage of Hearing Protection Device (HPD) for the workers such as ear plugs and ear muffs. The noise exposure of workers after usage of HPD can be calculated using the following formula:

Where NRR is the noise reduction rating of the HPD in dB.

Different area might have different noise level limits, and therefore area noise limits are useful. For example, in an unmanned mechanical room, the noise level can be high, for instance 110 dBA. However, inside of the site office, the allowable noise level is much lower, for example 50 dBA. This noise level shall be calculated to ensure compliance with the noise limit. Different companies might have different limits for this to ensure their employees’ health and productivity. If the area is indoor and the noise source is outdoor, then the interior noise level can be estimated using standards such as ISO 12354-3. 

The absolute noise limit is the highest noise level allowable at the plant, and shall not be exceeded at any times, including emergency. In most cases, the absolute noise limit for impulsive sound is 140 dBA. To ensure compliance with this requirement, potential high-level noise shall be calculated, for example safety valves.

During emergency, different noise sources than normal situation will be activated, such as flare, blowdown valves, fire pumps, and other equipment. In such cases, the sound from the alarm and Public Address system must be able to be heard by the workers inside of the plant. Normally the target for the SPL from the PAGA system should be higher than 10 dB above the noise level. Therefore, the noise level during emergency in each area should be well-known. 

Kategori
Asia Noise News

Dogs Can Experience Hearing Loss

Just like humans, dogs are sometimes born with impaired hearing or experience hearing loss as a result of disease, inflammation, aging or exposure to noise. Dog owners and K-9 handlers ought to keep this in mind when adopting or caring for dogs, and when bringing them into noisy environments, says Dr. Kari Foss, a veterinary neurologist and professor of veterinary clinical medicine at the University of Illinois at Urbana-Champaign.

In a new report in the journal Topics in Companion Animal Medicine, Foss and her colleagues describe cases of hearing loss in three working dogs: a gundog, a sniffer dog and a police dog. One of the three had permanent hearing loss, one responded to treatment and the third did not return to the facility where it was originally diagnosed for follow-up care.

The case studies demonstrate that those who work with police or hunting dogs “should be aware of a dog’s proximity to gunfire and potentially consider hearing protection,” Foss said. Several types of hearing protection for dogs are available commercially.

Just as in humans, loud noises can harm the delicate structures of a dog’s middle and inner ear.

“Most commonly, noise-induced hearing loss results from damage to the hair cells in the cochlea that vibrate in response to sound waves,” Foss said. “However, extreme noise may also damage the eardrum and the small bones within the inner ear, called the ossicles.”

Pet owners or dog handlers tend to notice when an animal stops responding to sounds or commands. However, it is easy to miss the signs, especially in dogs with one or more canine companions, Foss said.

“In puppies with congenital deafness, signs may not be noticed until the puppy is removed from the litter,” she said.

Signs of hearing loss in dogs include failing to respond when called, sleeping through sounds that normally would rouse them, startling at loud noises that previously didn’t bother them, barking excessively or making unusual vocal sounds, Foss said. Dogs with deafness in one ear might respond to commands but could have difficulty locating the source of a sound.

If pet owners think their pet is experiencing hearing loss, they should have the animal assessed by a veterinarian, Foss said. Hearing loss that stems from ear infections, inflammation or polyps in the middle ear can be treated and, in many cases, resolved.

Hearing-impaired or deaf dogs may miss clues about potential threats in their surroundings, Foss said.

“They are vulnerable to undetected dangers such as motor vehicles or predators and therefore should be monitored when outside,” she said.

If the hearing loss is permanent, dog owners can find ways to adapt, Foss said.

“Owners can use eye contact, facial expressions and hand signals to communicate with their pets,” she said. “Treats, toy rewards and affection will keep dogs interested in their training.” Blinking lights can be used to signal a pet to come inside.

Hearing loss does not appear to affect dogs’ quality of life, Foss said.”A dog with congenital hearing loss grows up completely unaware that they are any different from other dogs,” she said. “Dogs that lose their hearing later in life may be more acutely aware of their hearing loss, but they adapt quite well. A dog’s life would be significantly more affected by the loss of smell than by a loss of hearing.”

Written by:

Pitupong Sarapho (Pond)
Acoustical Engineer

Geonoise (Thailand) Co., Ltd.
Tel: +6621214399
Mobile: +66868961299
Email: pond@geonoise.asia

Credit: Diana Yates, University of Illinois at Urbana-Champaign

Kategori
Asia Noise News Building Accoustics

Railway Noise

Rail transport or train transport is one of the main transportation modes these days, both for transferring passengers and goods. Every day people commute to work and back home using trains in a form of subway systems, light rail transits and other types of rail transport. These types of system can create noise both to the passengers inside of the train as well as to the environment. In this article, we will discuss about noise source components that we hear daily both inside and outside of the train.

If we pay attention to the noise when we are on board of a train, there are more than one noise source that we can hear. The main sources for interior noise in a train are turbulent boundary layer, air conditioning noise, engine/auxiliary equipment, rolling noise and aerodynamic noise from bogie, as illustrated in the following figure.

By the way, we wrote and recorded the sound of Jakarta MRT. You can see the link below to help you imagine the train situation better.

Exploring Jakartan Public Transportation Through The Sound

Rolling noise is caused by wheel and rail vibrations induced at the wheel/rain contact and is one of the most important components in railway noise. This type of noise depends on both wheel and rail’s roughness. The rougher the surface of both components will create higher noise level both inside and outside of the train. To be able to estimate the airborne component from the rolling noise, we must consider wheel and track characteristics and roughness.

Another noise component that contributes a lot to railway noise is aerodynamic noise which can be caused by more than one sources. These types of sources may contribute differently to internal noise and external noise. For example, aerodynamic noise contributes quite significantly at lower speeds to internal noise while for external noise, it doesn’t contribute as much if the train speed is relatively low. For example, on the report written by Federal Railroad Administration (US Department of Transportation), it is stated that aerodynamic sources start to generate significant noise at speeds of approximately 180 mph (around 290 km/h). Below that speed, only rolling noise and propulsion/machinery noise is taken into consideration for external noise calculation. In addition to external noise, machinery noise also contributes to the interior noise levels. This category includes engines, electric motors, air-conditioning equipment, and so on. 

To perform the measurements of railway noise, there are several procedures that are commonly followed. For measurement of train pass-by noise, ISO 3095 Acoustics – Railway applications – measurement of noise emitted by rail bound vehicles, is commonly used. This standard has 3 editions with the first published in 1975, and then modified and approved in 2005 and again in 2013. The commonly used measures for train pass-by are Maximum Level (LAmax), Sound Exposure Level (SEL) and Transit Exposure Level (TEL).

For interior noise, the commonly used test procedure is specified in ISO 3381 Railway applications – Acoustics – Measurement of noise inside rail bound vehicles. This procedure specifies measurements in few different conditions such as measurement on trains with constant speed, accelerating trains from standstill, decelerating vehicles, and stationary vehicles. 

Written by:

Hizkia Natanael

Acoustical Design Engineer

Geonoise Indonesia

hizkia@geonoise.asia

Reference:

D. J. Thompson. Railway noise and vibration: mechanisms, modelling and means of control. Elsevier, Amsterdam, 2008

Federal Railroad Administration – U.S. Department of Transportation, High-Speed Ground Transportation Noise and Vibration Impact Assessment. DOT/FRA/ORD-12/15. 2012

USAThailandChinaIndonesiaVietnam