Kategori
Asia Noise News Building Accoustics

Noise and Vibration Monitoring for Construction Sites

The construction sites must control the noise and vibration that may affect the surroundings. Construction sites need to control the noise and vibration levels that they produce following the EIA standard.

In a densely populated city like Bangkok, most of the construction projects are surrounded by condominiums, offices or residential areas. The construction sites must control the noise and vibration that may affect the surroundings. Construction sites need to control the noise and vibration levels that they produce following the EIA standard.

To manage this, noise and vibration instruments are installed which automatically will send alarms to the construction company if the thresholds are exceeded.

Noise Monitoring Station

Sound level meter class 2 according to IEC61672-1 standard which can collect the data of SPL, LEQ and LMAX. These instruments are calibrated before they are installed at a construction site. The system has a LED display and warning light when noise levels in the site are over a trigger level, which is referred to in the standards for maximum sound levels around construction sites.

According to the announcement of National Environment Board no.15 BE.2540 (1997) in the topic of “Standard loudness”, the average sound 24 hour must not exceed 70 dBA and the maximum peak level must not exceed 115 dBA.

Sound level meter are designed to be used outdoors and an additional LED display was added by Geonoise which is a professional sound and vibration company. Sound level meter with LED display also can analyse the loudness in percentile (Statistical,Ln) or analyse the frequencies in 1/1 and 1/3 octave bands. In addition to storing vibration data, you can also create level notifications in Alarm Alert format before vibration levels exceed the standard value for monitoring the activities being performed.

Vibration Monitoring

In the construction industry, transportation Industry and most large industries vibrations will occur.
High vibration levels will cause structural damage to buildings, bridges, structures as well as nuisance or health risks to occupants in exposed (residential) buildings.

Therefore, it is necessary to comply with the standard of vibration in a building according to the Announcement of the National Environment Board Announcement No. 37, BE 2553 (2010) Re: Determination of Standard Vibration to Prevent Impact on Buildings and the measuring instruments need to comply with DIN45699-1.

At construction projects in Bangkok, most cause a lot of unwanted noise and vibrations. Vibration caused by construction projects are caused by piling work as well as the increased traffic of large trucks that enter and exit the construction site. To prevent that vibration levels will be exceeded, a vibration monitoring system will have to be installed.

The Announcement of the National Environment Board No. 37, BE 2553 Vibration standards to prevent impacts on buildings is the main regulation to comply with for construction sites in Thailand. The vibration standards are derived from DIN 4150-3 whereas buildings are classified into 3 types.

Building types according to DIN 4150-3:

  • Type 1 buildings such as commercial buildings, public buildings, large buildings, etc.
  • Type 2 buildings such as residential buildings, dormitories, hospitals, educational institutions, etc.
  • Type 3 buildings, such as archaeological sites or buildings that cultural values but not strong, etc.

In addition to storing vibration data, you can also create level notifications in Alarm Alert format before vibration level exceed the standard value for monitoring the activities being performed.

USAThailandChinaIndonesiaVietnam